ZM coating weight tells you how much zinc-aluminium-magnesium alloy is plated on the steel surface, measured in grams per square metre over both faces. For S220GD+ZM used outdoors — solar racking, purlins, fencing, agricultural buildings — picking the right ZM grade is the difference between a 15-year and a 30-year service life.
The ZM family is defined in EN 10346:2015. Common grades for S220GD substrate are ZM90 through ZM310.
| Coating Designation | Triple Spot (g/m²) | Single Spot (g/m²) | Typical Thickness per Side (µm) |
|---|---|---|---|
| ZM90 | 90 | 75 | 7 |
| ZM120 | 120 | 100 | 9 |
| ZM150 | 150 | 120 | 11 |
| ZM180 | 180 | 150 | 14 |
| ZM220 | 220 | 185 | 17 |
| ZM275 | 275 | 235 | 21 |
| ZM310 | 310 | 265 | 24 |
Triple spot is the average over three test areas; single spot is the minimum anywhere on the coil. Thickness is calculated using the ZM alloy density of about 6.2 g/cm³.
A common buyer question: is ZM120 lighter than Z275? Numerically yes, but performance is equal or better. The 1–3% magnesium in the alloy forms a stable corrosion-product film on cut edges and scratches, which is exactly where pure zinc fails first. In independent tests, ZM120 gives corrosion protection not less than Z275, and ZM310 matches Z600 — so you can specify a thinner, lighter ZM layer and still reach the same design life.
| Corrosion Class (ISO 9223) | Typical Environment | Recommended ZM on S220GD |
|---|---|---|
| C2 — Low | Dry inland, heated indoor | ZM90 |
| C3 — Medium | Urban, light industrial | ZM120 – ZM150 |
| C4 — High | Coastal, agricultural | ZM180 – ZM275 |
| C5 — Very high | Offshore, heavy industrial | ZM275 – ZM310 |
For outdoor structures the practical minimum is ZM120. Anything lighter belongs to indoor or sheltered service only.
Avoid ambiguous wording like “galvanized”. Use the EN 10346 designation: S220GD+ZM180 means 220 MPa minimum yield, hot-dip coated, ZM at 180 g/m² triple spot. Add the surface finish (zero spangle, skin passed, oiled or unoiled) and the standard test certificate (EN 10204 3.1).
1. Can I order a ZM coating weight outside the EN 10346 table?
Yes, many mills accept non-standard weights between two listed grades, for example ZM160. Expect a small MOQ premium.
2. Is thicker ZM always better for outdoor use?
Not necessarily. Once the self-healing layer is established, additional mass gives diminishing returns. Pick the grade that matches the corrosion class and design life.
3. Does ZM coating need post-paint for outdoor colour?
Not for corrosion protection, but for colour you can powder coat or liquid paint directly on ZM after a standard pre-treatment — no special primer required.
4. How does ZM differ from AZ (Galvalume) on the same base steel?
AZ is roughly 55% Al / 43% Zn / 1.5% Si and excels at high temperature. ZM uses much less aluminium but adds magnesium, which gives far better cut-edge protection — the main reason ZM is preferred for outdoor structural parts.
Tell us your project country, target service life and profile drawing. We will recommend the most cost-effective ZM grade and supply mill-trial salt-spray data. Reach our sales team through the contact page.